| Technical Data |
Gases Oxygen (O2) | Alarms 3 alarm points User adjustable within the detection range |
Detection range 0-25% volume | Alarm Functions Available Over range / under range Latching / non-latching Resettable / non-resettable Hysteresis adjustable Delay-time 0 to 2 minutes Alarm thresholds adjustable |
Detection principal Zirconia oxide |
Expected sensor life 5 years + |
Gas supply Diffusion | Relays 3 alarm points, 1 fault – voltage free Factory settings A1 - strobe A2 - open A3 - horn Fault - open Voltage: 250 VAC 50/60 Hz or 250 VDC maximum |
Humidity 0 to 99 %r.h. non-condensing |
Temperature range 32 to +122°F / 0 to +55°C |
Pressure 920 to 1,100 hPA | Output signal Linear 4-20 mA |
Power supply 24 VDC wall pack | Horn Low - 70 dB at 10 ft. per UL 464 High - 83 dB at 10 ft. per UL 464 |
Weight 6.5 lbs. (2.95 kg) | Strobe Light output on axis (cd) Low - 35 High - 68 |
Display 3-digit LED display for linear measurement values, service 1 LED green – operational status 1 LED yellow – fault 3 LEDs red – alarm Display of maximum / minimum values | Dimensions 11x7x2.75 inches (27.9x17.8x7 cm) (HxWxD) |