GfG 4100 DP Control Panel
View Full-Size Image


GfG 4100 DP Control Panel

Price per Unit (piece): Call for Pricing

Ask a question about this product

GMA 4100-DP Control Panel
Dew Point


Reading of dew point values on a 3-digit display

·                     Menu display

·                     3 variably adjustable alarm thresholds

·                     Peak value memory

·                     Adjustable relay functions: NC / NO contact, open-circuit / closed circuit

·                     Alarm hystereses prevents “flickering” of relays

·                     4 - 20 mA analog output signal

 
GMA 4100-DP Control Panel

The GMA 4100-DP continuously provides information on the measured dew point level, exceeded alarm thresholds and its operational status. As soon as the dew point exceeds one of the three pre-set levels, the GMA 4100-DP gives a warning by means of the LED display, the console mounted horn/strobe, and controls the relevant alarm relays. In addition to this, the GMA 4100-DP provides the measurement value as an analog output signal for further evaluation. The GMA 4100-DP is easy to operate and maintenance-free. The dew point sensor is self calibrating and lasts for years. Should unexpected failures or system faults occur, the comprehensive failure recognition allows a quick and specific service.
Alarm points

Each alarm can be adjusted separately. Relay chatter is eliminated with the adjustable alarm delay. The alarm point values can be freely adjusted using the keypads on the controller.
Alarm relays
The controller provides four voltage-free relays for the three alarms and one fault warning. The relays may be used to control additional alarm devices like lights or horns.
Additional features

The 4100 control panel stores peak values and offers an additional 4-20 mA output.

The operation and performance of Vaisala dew point transmitters is unique. The lasting high performance is achieved using Vaisala DRYCAP® polymer sensor technology, which incorporates innovations like the patented auto calibration feature and sensor purge. These result in dew point measurement with excellent long-term stability, i.e. very small drift. This in turn means very low maintenance needs and costs, which is important in equipment like small-sized air dryers.
Technical Data
Climate Conditions For Operation
32 to 131°F (0 to +55°C), 0 to 99 % r.h.
Power Source
24 VDC wall pack
Output signals Analog Outputs for Measured Value
4 to 20 mA, maximum load 300
Dimensions
12x12x3.5 inches (304.8x304.8x88.9 mm) (WxHxD)
Relays Maximum Switch Voltage
250 VAC 50/60 Hz or 250 VDC
Alarms
3 adjustable alarm points
1 fault alarm
Maximum Switch Current
4 A AC/DC
Relay outputs and mains entry are operation insulated
Alarm functions
Hysteresis adjustable
Delay-time 0 to 2 minutes
Alarm thresholds completely adjustable (above zero only)
Maximum Switch Performance
1,000 VAC
Relay outputs
4 voltage-free relays for alarm and fault
Normally closed contact (NC)
Normally open contact (NO)
Load: 250 V AC, 4 A
Protective separation
By safety transformer
Protective insulation
As per EN 61010 up to over voltage category III and soiling degree 2
Display
3-digit LED display
1 LED green – operational status
1 LED yellow – fault
3 LEDs red – alarm
Dew Point Temperature Range
-60 to +60°C
Function keys
Push-button operation for alarm points, function test, and relay test
 
      
 





more categories


Portables

Fixed

Stand - Alone

Manufacturers




Contact Us

668 Easton Ave
Somerset, NJ 08873
PH 800-452-6822
Fax 732-828-4912
sales@emlinc.com
service@emlinc.com
SERVICE RETURN FORM
Adobe Acrobat .pdf
Microsoft Office .doc
Register Here For Product News and Updates!
Registration is also needed for online purchases.
(Coming Soon!) Smile
PRIVACY POLICY:
We do not sell, rent or disclose your personal information to anyone! EVER!!!

SAFETY ADVISORIES

Products at a glance...

CTX300
CTX300
Biosystems ToxiLTD
Biosystems ToxiLTD
GfG Microtector G333
GfG Microtector G333
BM25
BM25
BW Micro Dock II
BW Micro Dock II
madur GA40T+
madur GA40T+
GfG 4100 DP Control Panel
GfG 4100 DP Control Panel
MX42A
MX42A
BW Gas Alert Micro 5
BW Gas Alert Micro 5
Howard Leight QM24+
Howard Leight QM24+
Howard Leight Laser Lite
Howard Leight Laser Lite
GfG GMA 80A
GfG GMA 80A
GfG G450 (15% OFF!!)
GfG G450 (15% OFF!!)
DBI ExoFit™ VELCRO®
DBI ExoFit™ VELCRO®
SPERIAN TUFF-COAT
SPERIAN TUFF-COAT
GfG EC30 AutoCal
GfG EC30 AutoCal
SURVIVAIR ONE-Fit NBW95V
SURVIVAIR ONE-Fit NBW95V
Crowcon Flamgard Plus
Crowcon Flamgard Plus

WINTER SPECIALS!!!

MX4 iQuad (15% OFF!)
MX4 iQuad (15% OFF!)
Call for Pricing
V!SA (SPECIAL PRICING)
V!SA (SPECIAL PRICING)
Call for Pricing
BW Gas Alert Max XT (15% OFF!)
BW Gas Alert Max XT (15% OFF!)
Call for Pricing
GfG G450 (15% OFF!!)
GfG G450 (15% OFF!!)
Call for Pricing

Customer Poll

How often does your company calibrate its gas monitors?
 

OSHA Bulletin

OSHA bulletin on Calibration Frequency. Registration Required.

Login/Register






Who's Online

We have 18 guests online

Employee Portal

Webmail Access

Copyright © 2010 Electronic Measurement Labs Inc.. All Rights Reserved. Designed by JoomlArt.com.